Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Front Neurol ; 15: 1367860, 2024.
Article in English | MEDLINE | ID: mdl-38645747

ABSTRACT

Background: Excessive daytime sleepiness (EDS) is a cause of low quality of life among obstructive sleep apnoea (OSA) patients. Current methods of assessing and predicting EDS are limited due to time constraints or differences in subjective experience and scoring. Electroencephalogram (EEG) power spectral densities (PSDs) have shown differences between OSA and non-OSA patients, and fatigued and non-fatigued patients. Therefore, polysomnographic EEG PSDs may be useful to assess the extent of EDS among patients with OSA. Methods: Patients presenting to Israel Loewenstein hospital reporting daytime sleepiness who recorded mild OSA on polysomnography and undertook a multiple sleep latency test. Alpha, beta, and delta relative powers were assessed between patients categorized as non-sleepy (mean sleep latency (MSL) ≥10 min) and sleepy (MSL <10 min). Results: 139 patients (74% male) were included for analysis. 73 (53%) were categorized as sleepy (median MSL 6.5 min). There were no significant differences in demographics or polysomnographic parameters between sleepy and non-sleepy groups. In multivariate analysis, increasing relative delta frequency power was associated with increased odds of sleepiness (OR 1.025 (95% CI 1.024-1.026)), while relative alpha and beta powers were associated with decreased odds. The effect size of delta PSD on sleepiness was significantly greater than that of either alpha or beta frequencies. Conclusion: Delta PSD during polysomnography is significantly associated with a greater degree of objective daytime sleepiness among patients with mild OSA. Further research is needed to corroborate our findings and identify the direction of potential causal correlation between delta PSD and EDS.

2.
Sleep Med ; 117: 201-208, 2024 May.
Article in English | MEDLINE | ID: mdl-38583319

ABSTRACT

OBJECTIVE: The current electroencephalography (EEG) measurement setup is complex, laborious to set up, and uncomfortable for patients. We hypothesize that differences in EEG signal characteristics for sleep staging between the left and right hemispheres are negligible; therefore, there is potential to simplify the current measurement setup. We aimed to investigate the technical hemispheric differences in EEG signal characteristics along with electrooculography (EOG) signals during different sleep stages. METHODS: Type II portable polysomnography (PSG) recordings of 50 patients were studied. Amplitudes and power spectral densities (PSDs) of the EEG and EOG signals were compared between the left (C3-M2, F3-M2, O1-M2, and E1-M2) and the right (C4-M1, F4-M1, O2-M1, and E2-M2) hemispheres. Regression analysis was performed to investigate the potential influence of sleep stages on the hemispheric differences in PSDs. Wilcoxon signed-rank tests were also employed to calculate the effect size of hemispheres across different frequency bands and sleep stages. RESULTS: The results showed statistically significant differences in signal characteristics between hemispheres, but the absolute differences were minor. The median hemispheric differences in amplitudes were smaller than 3 µv with large interquartile ranges during all sleep stages. The absolute and relative PSD characteristics were highly similar between hemispheres in different sleep stages. Additionally, there were negligible differences in the effect size between hemispheres across all sleep stages. CONCLUSIONS: Technical signal differences between hemispheres were minor across all sleep stages, indicating that both hemispheres contain similar information needed for sleep staging. A reduced measurement setup could be suitable for sleep staging without the loss of relevant information.


Subject(s)
Sleep Stages , Sleep , Humans , Electroencephalography/methods , Polysomnography , Electrooculography
3.
J Sleep Res ; : e13977, 2023 Jul 03.
Article in English | MEDLINE | ID: mdl-37400248

ABSTRACT

Sleep recordings are increasingly being conducted in patients' homes where patients apply the sensors themselves according to instructions. However, certain sensor types such as cup electrodes used in conventional polysomnography are unfeasible for self-application. To overcome this, self-applied forehead montages with electroencephalography and electro-oculography sensors have been developed. We evaluated the technical feasibility of a self-applied electrode set from Nox Medical (Reykjavik, Iceland) through home sleep recordings of healthy and suspected sleep-disordered adults (n = 174) in the context of sleep staging. Subjects slept with a double setup of conventional type II polysomnography sensors and self-applied forehead sensors. We found that the self-applied electroencephalography and electro-oculography electrodes had acceptable impedance levels but were more prone to losing proper skin-electrode contact than the conventional cup electrodes. Moreover, the forehead electroencephalography signals recorded using the self-applied electrodes expressed lower amplitudes (difference 25.3%-43.9%, p < 0.001) and less absolute power (at 1-40 Hz, p < 0.001) than the polysomnography electroencephalography signals in all sleep stages. However, the signals recorded with the self-applied electroencephalography electrodes expressed more relative power (p < 0.001) at very low frequencies (0.3-1.0 Hz) in all sleep stages. The electro-oculography signals recorded with the self-applied electrodes expressed comparable characteristics with standard electro-oculography. In conclusion, the results support the technical feasibility of the self-applied electroencephalography and electro-oculography for sleep staging in home sleep recordings, after adjustment for amplitude differences, especially for scoring Stage N3 sleep.

SELECTION OF CITATIONS
SEARCH DETAIL
...